Wenzhou Natural Automation Equipment Co., Ltd.
Main products:Thermostat
Products
Contact Us
  • Contact Person : Ms. Guo Dilys
  • Company Name : Wenzhou Natural Automation Equipment Co., Ltd.
  • Tel : 0086-577-62787886,62787885
  • Fax : 0086-577-62768368
  • Address : Zhejiang,wenzhou,No. 8th, Xiangyang Road, Shangyuan Village, Liushi Town, Yueqing City, Wenzhou City, Zhejiang 325604 China
  • Country/Region : China
  • Zip : 325604

magnetic latching relay

magnetic latching relay
Product Detailed
Reliable, energy saving, precision

Product features

Low power consumption, strong load capacity, can switch to 80A/250VAC;

According to customer requirements of welding accessories

Typical use

Intelligent electric energy meter prepaid electric energy meter electric power remote composite switch control over and under voltage protector

Main technical parameters

Contact parameters

 

 

 

Performance parameters

Contact form

1B

Closing time ( rated voltage )

20ms Max

Contact resistance(1A 6VDC)

Max.1.5mΩ(1A 6VDC)

Opening time ( rated voltage )

20ms Max

contact material

silver alloy

Medium

Withstand voltage

Contact with the coil

4000VAC 50/60Hz(1Min)

Contact load

( resistive load )

60A/80A /250VAC

Disconnect between contacts

1500VAC 50/60Hz(1Min)

The maximum switching voltage

250 VAC

The maximum switching current

60A/80A

insulation resistance

500MΩMin.(500VDC)

The maximum switching power

15KVA/20KVA

ambient temperature

-40°C~+70°C

relative humidity

45%-90%RH

lifetime

mechanical life

5×105OPS

vibrancy

10-55Hz,1.5mm

lash

98m/s2

Electrical life

1×104PS

Weight ( no attachments )

36g

Ordering mark

DL-902A

80A

1B

9VDC

S

XX

 

product model

contact current

Contact form

Coil voltage

Coil form

External accessories

DL-902A

80A

1B:1NC

6,9,12,24,48V

S::one coil

D:twin coil

According to customer requirements

                    

 

 

          

     DL-902A-60  magnetic latching relay  

Coil parameter specification table(20°C)

Voltage

Code

rated voltage(VDC)

coil resistance(Ω)±10%

Coil power dissipation(W)

sealing voltage(VDC)

off voltage(VDC)

Overload voltage(VDC)

pulse width(ms)

one coil

twin coil

one coil

twin coil

06

6VDC

36

18/18

1.0W

2.0W

≤70%

≤70%

≤150%

≥60ms

09

9VDC

80

40/40

12

12VDC

140

70/70

24

24VDC

576

288/288

48

48VDC

2304

1150/1150

           

Outline dimensions, wiring diagram ( unit: mm)